Miretti utilizes gas detection in it’s Zone 2 solutions called EOS XD, EOS XE . In these cases gas detection is only one element of the complete Miretti system.

EOS for not Classified Locations

If you are looking for a gas detection system that will provide added safety in areas that are not formally classified but where there may be some risk of explosion, then choose EOS system. EOS can be fitted locally by a competent person to almost any plant equipment to detect a flammable gas/vapour. EOS system safety for non classified areas.

  • Rapid Startup | with compulsary gas test so you know it's working. Long life test gas cylinder.
  • Detection Technology | Using pellister technology (it detects a large range of gases) . No preset recording
  • Sounder | Audible alarm upon detection and equipment shutdown.
  • Design | Ergonomic, solid design, with ambient temp. -20°C to +40°C, enclosures are rated comply with IP65.
  • Automatic timer shutdown
  • Fail-safe | Tested to rigorous standards with fail safe operating sequence.
  • Not for Zoned areas | Does not allow equipment to be used within Zone 1, 2, 21 or 22 hazardous areas.
  • Equipment shutdown | Can be used as an alternative to the air intake overspeed shutdown valve and spark arrester approach.

EOS XE

The EOS XE is Miretti 's Active protection system for all types of Electric equipment working in Zone 2 areas. This means that the system is continuously checking for an explosive atmosphere and will shut the equipment down if necessary. Tested by a Notified Laboratory ATEx , the EOS XE system ensures that the ignition sources are protected but retains all the ergonomic and performance benefits of the original equipment. All conversions take place at Miretti factories.

Features include:

A solution for electric equipment in Zone 2

  • System EOS XE | Systems cover IIA or IIB, IIB + H2, T3, T4 and T5.
  • Forced gas test | to ensure system integrity prior to operation.
  • Audible and visible alarm | at 10% 25% LEL followed by shutdown at 25%.
  • Components assessed/modified | All arcing, sparking and hot components are risk assessed and fitted with restricted breathing enclosures to restrict the ingress of the flammable gas / vapour. DC motors are installed into Ex “nR” or Ex “d” enclosures.
  • Temperature monitoring | of hot surfaces to T2 (300°C), T3 (200°C), (T4 135°C) or T5 (100°C).
  • Gas sensing head | is certified for use with gas groups IIA or IIB or IIB + H2.
  • Forks | clad in stainless steel
  • Certification | Certified as Category 3G or Declaration of conformity equipment for use in Zone 2 areas only

EOS XD

The EOS XD is Miretti 's Active protection system for all types of Diesel equipment working in Zone 2 areas. This means that the system is continuously checking for an explosive atmosphere and will shut the equipment down if necessary. Tested by a Notified Laboratory Atex, the EOS XD system ensures that the ignition sources are protected but retains all the ergonomic and performance benefits of the original equipment. All conversions take place at Miretti factories .

Features include:

A solution for electric equipment in Zone 2

  • System EOS XD | Systems cover IIA or IIB, IIB+H2, T2, T3, T4 or T5 temperatures
  • Forced gas test | to ensure system integrity prior to operation.
  • Audible and visible alarm | at 10% LEL followed by shutdown at 25%
  • Engine modification | according to EN 1834 standards
  • Components assessed/modified | All arcing, sparking and hot components are risk assessed and fitted with restricted breathing enclosures according to EN 1834 standards; DC motors are installed in Ex “e” or Ex “d” enclosures
  • Temperature monitoring | of hot surfaces to T2 (300°C), T3 (200°C), (T4 135°C) or T5 (100°C).
  • Gas sensing head | is certified for use with gas groups IIA or IIB or IIB + H2.
  • Forks | clad in stainless steel
  • Certification | Certified as Category 3G or Declaration of conformity equipment for use in Zone 2 areas only
  • Exhaust gases cooled | Water exhaust gas cooler Exhaust gases cooled cooled limits surface and exhaust temperatures to the specified temperature class.
  • Shutdown valve | inlet shutdown valve for automatic engine overspeed and manual shutdown

Ex CONVERSIONS FOR

ELECTRIC TRUCKS

2G conversions

Miretti 2G conversions provides explosion protection for all types of electric equipment. The system works by enclosing or eliminating all ignition sources.

Features include:

PHOTO GALLERY
  • Conversions 2G – Gas group IIA / IIB / IIC, IIB+H2, Gas Temperature classes T3 / T4 / T5
  • Certification | Certified as Category 2G equipment for use in Zone 1 areas (can also be used in Zone 2)
  • Motors | Certified motors Ex e / Ex d
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within an Ex'd' explosion proof enclosure.
  • Battery | Battery is designed and tested in according to EN 60079-7.
  • Battery isolator | removes all power from the protected vehicle.
  • Forks | clad in stainless still

3G conversions

Miretti 3G conversions provides explosion protection for all types of electric equipment. The system works by enclosing or eliminating all ignition sources.

Features include:

  • Conversions 3G – Gas group IIA / IIB / IIC, IIB+H2, Gas Temperature classes T3 / T4 / T5
  • Certification | Certified as Category 3G equipment for use in Zone 2 areas only
  • Motors | Ex nA A.C.
  • Motors | Ex d D.C. motors designed for use in Zone 2 only
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within an Ex'd' explosion proof enclosure.
  • Battery | Battery Ex nA
  • Battery isolator | removes all power from the protected vehicle.
  • Forks | clad in stainless still

2D conversions

Miretti offer a complete certified solution for electric vehicles required to work within Zone 21 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Components should not exceed the layer ignition temperature.

3D conversions

Miretti offer a complete certified solution for electric vehicles required to work within Zone 22 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Components should not exceed the layer ignition temperature.

Ex CONVERSIONS FOR DIESEL TRUCKS

2G conversions

Miretti 2G conversions provides explosion protection for all types of diesel equipment. The system works by enclosing or eliminating all ignition sources. With full certification Miretti 2G conversion is for Zone 1 areas. The protection controls engine surface temperature, prevents flame or spark omission from the exhaust system and ensures the prevention or air inlet flashback and engine overspeed.

Features include

PHOTO GALLERY
  • Conversions 2G | Gas group IIA / IIB / IIB+H2, Gas Temperature classes T2 /T3 / T4 / T5
  • inlet shutdown valve | for automatic and manual shutdown
Flameproof box and exhaust system
  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator.
  • Flame arrestors | suitable for group IIA and IIB gasses
  • On-board electric starting | allows for options such as lighting and sounders.

3G conversions

Miretti 3G conversions provides explosion protection for all types of diesel equipment. The system works by enclosing or eliminating all ignition sources. With full certification Miretti 3G conversion is for Zone 2 areas. The protection controls engine surface temperature, prevents flame or spark emission from the exhaust system and ensures the prevention or air inlet flashback and engine overspeed.

Features include

  • Conversions 3G | Gas group IIA / IIB / IIB+H2, Gas Temperature classes T2 / T3 / T4 / T5
  • inlet shutdown valve | for automatic and manual shutdown

Flameproof box and exhaust system

  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator.
  • Flame arrestors | suitable for group IIA and IIB gasses
  • On-board electric starting | allows for options such as lighting and sounders.

2D conversions

Miretti offer a complete certified solution for diesel vehicles required to work within Zone 21 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Componenets should not exceed the layer ignition temperature.

3D conversions

Miretti offer a complete certified solution for diesel vehicles required to work within Zone 22 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Components should not exceed the layer ignition temperature.

EX/EE CONVERSIONS FOR ELECTRIC TRUCKS

Class I, Division 1; Class II, Dvision1, EX

Miretti EX conversions provides explosion protection for all types of electric equipment. The system works by enclosing or eliminating all ignition sources.

Features include:

  • Conversions EX – Gas group C and D, Dust group G, Temperature class 160 °C
  • Certification | Certified as EX equipment for use in Division 1 areas (can also be used in Division2 )
  • Motors | Certified motors as explosion proof
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within an explosion proof enclosure.
  • Battery | Battery is designed and tested as EX (UL 583) and fitted with explosion proof plugs and sockets and fuses box
  • Battery isolator | removes all power from the protected vehicle.
  • Forks | clad in stainless still

Class I, Division 1; Class II, Division 2, EE

Miretti EE conversions provides explosion protection for all types of electric equipment. The system works by enclosing all ignition sources.

Features include:

  • Conversions EE – Gas group C and D, Dust group G, Gas Temperature class 160°C
  • Certification | Certified as EE equipment for use in Division2 areas only
  • Motors | Explosion proof enclosed if DC motors, mechanically protecting enclosures if AC motors
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within explosion proof enclosure.
  • Battery | Battery is spark proof and mechanically protected.
  • Battery isolator | removes all power from the protected vehicle.
  • Forks | clad in stainless still

Miretti offer a complete certified solution for electric vehicles required to work within Division 1 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including explosion proof and dust proof enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible gases and dusts.

DX/DY CONVERSIONS FOR DIESEL TRUCK

Class I, Division 1; Class II, Division 1, DX

Miretti CI D1, CII D1 conversions provides explosion protection for all types of diesel equipment. The system works by enclosing or eliminating all ignition sources. With full certification Miretti CI D1, CII D1 conversions are for Division 1 areas . The protection controls engine surface temperature, prevents flame or spark emission from the exhaust system and ensures the prevention or air inlet flashback and engine over speed.

Features include

  • Conversions CI D1, CII D1 – Gas group D, Dust group G, Gas Temperature class 160 °C
  • inlet shutdown valve | for automatic and manual shutdown

Flameproof box and exhaust system

  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator and fuses
  • Flame arrestors | suitable for group D gasses G
  • On-board electric starting | allows for options such as lighting and sounders.

Class I, Division 2; Class II, Division 2, DY

Miretti CI D2, CII D1 conversions provides explosion protection for all types of diesel equipment. The system does works by enclosing or eliminating all ignition sources.
With full certification Miretti CI D2, CII D2 conversions are for Division 2 areas .
The protection controls engine surface temperature, prevents flame or spark omission from the exhaust system and ensures the prevention or air inlet flashback and engine overspeed.
Features include

  • Conversions CI D2, CII D2 – Gas group D, Dust group G, Gas Temperature classes 175 °C
  • inlet shutdown valve | for automatic and manual shutdown

Flameproof box and exhaust system

  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator.
  • Flame arrestors | suitable for group D gasses
  • On-board electric starting | allows for options such as lighting and sounder

Miretti Equipment is modified using various protection methods including explosion proof and dust proof enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible gas and dusts.

Ex CONVERSION for AERIAL PLATFORM LIFT

Conversion 2G

Miretti 2G conversions provides explosion protection for all types of electric equipment. The system works by enclosing or eliminating all ignition sources.

Features include:

PHOTO GALLERY
  • Conversions 2G – Gas group IIA / IIB / IIB+H2, Gas Temperature classes T3 / T4 / T5
  • Certification | Certified as Category 2G equipment for use in Zone 1 areas (can also be used in Zone 2)
  • Motors | Certified motors Ex e / Ex d
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within an Ex'd' explosion proof enclosure.
  • Battery | Battery is designed and tested to EN 60079-7 Ex'e' and fitted with Ex'd' plugs and sockets.
  • Battery isolator | removes all power from the protected vehicle.

Conversion 3G

Miretti 3G conversions provides explosion protection for all types of electric equipment. The system works by enclosing or eliminating all ignition sources.

Features include:

  • Conversions 3G – Gas group IIA / IIB / IIC, Gas Temperature classes T3 / T4 / T5
  • Certification | Certified as Category 3G equipment for use in Zone 2 areas only
  • Motors | Ex nA A.C. motors, Ex d D.C. motors designed for use in Zone 2 only
  • Temperature monitoring | of hot surfaces
  • Frame leakage monitoring | Highlights electrical failure before risk of ignition source
  • Components enclosed | All arcing and sparking components are placed within an Ex'd' explosion proof enclosure.
  • Battery | Battery Ex nA
  • Battery isolator | removes all power from the protected vehicle.

Conversion 2D

Miretti offer a complete certified solution for electric vehicles required to work within Zone 21 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Components should not exceed the layer ignition temperature.

Conversion 3D

Miretti offer a complete certified solution for electric vehicles required to work within Zone 22 potentially explosive atmospheres. Miretti Equipment is modified using various protection methods including IP enclosures, controlling surface temperatures and elimination of any mechanically generated ignition sources. The conversion of the equipment is realized taking into account the different kind of combustible dusts. Ignition temperature - Cloud (C) and Layer (L) | There are two ignition temperatures, layer ignition (on a surface) and cloud (in the air). Components should not exceed the layer ignition temperature.

Ex M2 CONVERSIONS

M2 conversions Coal Mines

Miretti M2 conversions provides explosion protection for all types of diesel equipment. The system works by enclosing or eliminating all ignition sources. With full certification Miretti M2 conversions are for M2 areas. The protection controls engine surface temperature, prevents flame or spark omission from the exhaust system and ensures the prevention or air inlet flashback and engine overspeed.

Features include

PHOTO GALLERY
  • Conversions M2 | Gasses mines, Temperature ≤ 150 °C ≤ 450 °C
  • inlet shutdown valve | for automatic and manual shutdown

Flameproof box and exhaust system:

  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator.
  • Flame arrestors | suitable for group I M2
  • On-board electric starting | allows for options such as lighting and sounders.

M2 conversions for Tunnel

Miretti M2 conversions provides explosion protection for all types of diesel equipment. The system works by enclosing or eliminating all ignition sources. With full certification Miretti M2 conversions are for M2 areas. The protection controls engine surface temperature, prevents flame or spark omission from the exhaust system and ensures the prevention or air inlet flashback and engine overspeed.

Features include

PHOTO GALLERY
  • Conversions M2 | Gasses mines, Temperature ≤ 150 °C ≤ 450 °C
  • inlet shutdown valve | for automatic and manual shutdown

Flameproof box and exhaust system

  • Water cooled exhaust gas cooler | limits surface and exhaust temperatures to the specified temperature class.
  • Flameproof main enclosure | incorporates an integral battery isolator.
  • Flame arrestors | suitable for group I M2
  • On-board electric starting | allows for options such as lighting and sounders.

GAS AND VAPOUR ZONES

Zone 0 (Cat. 1G)

An area in which a dangerous explosive gas atmosphere is present constantly, frequently or for a long period of time. These conditions occur, generally speaking, inside containers, pipework or receptacles.

Zone 1 (Cat. 2G)

An area in which a dangerous explosive gas atmosphere might be formed during normal functioning.

Zone 2 (Cat. 3G)

An area in which a dangerous explosive gas atmosphere should not occur during normal functioning, or if this happens, it is only for a short time.

DUST ZONES

Zone 20 (Cat. 1D)

An area in which a dangerous explosive atmosphere formed in the air by a dust cloud is present constantly, frequently or for a long time. These conditions occur, generally speaking, inside containers, pipework or receptacles. Layers of dust might be formed. These layers alone do not form a Zone 20. Areas excluded from this zone are those where although dust layers exist, they are not present constantly, frequently or for a long time.

Zone 21 (Cat. 2D)

An area in which an explosive dangerous atmosphere, formed in the air by a dust cloud, has a good possibility of being formed during normal working conditions. This zone might include, among others, areas near to the dust loading and unloading points, areas where dust may be deposited, areas where there is a high possibility of explosive concentrations being formed between combustible dusts and air during normal functioning

Zone 22 (Cat. 3D)

An area in which a dangerous explosive atmosphere, formed in the air by a dust cloud, has a minimal possibility of being formed during normal functioning. If this should occur it is only for a very short time or when layers of dust are present. This zone includes, among others, areas near equipment, protective systems and components containing dusts, from which dust may escape and deposit itself.

Conversions for U.S. and Canadian according to the UL Standards

Classification of hazardous locations

Class I Division 1

Class I, Division 1 locations are those where the explosion hazard exists under normal operating conditions. The area may be hazardous all or most of the time, or it may only be hazardous some of the time. Division 1 also includes locations where breakdown or faulty operation of electrical equipment or processes might release ignitable concentrations of flammable gases or vapors, and might also cause simultaneous failure of electrical equipment in such a way as to directly cause the electrical equipment to become a source of ignition. An example of such a location might be an area where a flammable liquid is stored under cryogenic conditions, and a leak of the extremely low temperature liquid directly onto electrical equipment could cause failure of the electrical equipment at the same time the vapors of the evaporating liquid are within the flammable range.

Class I Division 2

Class I, Division 2 locations are those where ignitable concentrations of flammable gases or vapors are not normally present, but could be present in the event of a fault, such as a leak at a valve in a pipeline carrying flammable liquids. Division 2 locations also often exist around Division 1 locations where there is no barrier or partition to separate the Division 1 space from a non-hazardous location, or where ventilation failure (an abnormal condition) might extend the area where flammables exist under normal conditions. Electrical equipment approved for Class I, Division 1 locations is also suitable for use in Division 2 locations.

Class II Division 1

A Class II, Division 1 location is one where combustible dust is normally in suspension in the air in sufficient quantities to produce ignitable mixtures, or where mechanical failure or abnormal operation of equipment or machinery might cause an explosive or ignitable dust-air mixture to be produced, and might also provide a source of ignition through simultaneous failure of electrical equipment. A Class II, Division 1 location also exists where combustible dusts of an electrically conductive nature may be present in hazardous quantities (Group E locations). The term “hazardous quantity” is intended to mean those locations where the dust may not be in suspension in the air in sufficient quantity to cause an explosion, but might have settled on electrical equipment so that the electrically conductive particles can penetrate the openings in the electrical equipment enclosure and cause an electrical failure, or where the dust can get into motor bearings and cause excessive temperatures because of bearing failure.

Class II Division 2

A Class II, Division 2 location is one where combustible dust is not normally in the air in quantities sufficient to produce explosive or ignitable mixtures, and dust accumulations are not normally sufficient to interfere with the normal operation of electrical equipment, such as clogging ventilating openings or causing bearing failure. It includes locations where combustible dust may be in suspension in the air only as a result of infrequent malfunctioning of handling or processing equipment, and those locations where dust accumulation may be on or in the vicinity of the electrical equipment and may be sufficient to interfere with the safe dissipation of heat from the equipment, or may be ignitable by abnormal operation or failure of the electrical equipment.

EXPLOSION PROOF COMPONENTS

PHOTO GALLERY


The company Miretti is specialized in manufacturing and designing components for processing flameproof certificates, suitable for different countries.
Miretti designing and manufacturing parts fit for all types of processing for a wide range of vehicles manufactured by different manufacturers. Specifically designed and fit the mechanical and electronic parts that must be protected in ATEX design studied by professional technicians, able to maintain the original characteristics of the mechanical means. Miretti also produces the conversion kit, designed for mounting of components from the original producer, particularly in the offshore sector.
Miretti is a qualified partner capable of meeting all requirements for the processing of the media who work in hazardous areas to ensure a safe work environment